Opinion appears to be somewhat divided on the autoignition temperature of sulfur. Fisher Scientific says 232 degrees C.


James A. Kaufman, PhD

Founder/President Emeritus


The Laboratory Safety Institute (LSI)

A Nonprofit Educational Organization for Safety in Science, Industry, and Education

192 Worcester Street, Natick, MA 01760-2252

(O) 508-647-1900 (F) 508-647-0062 (C) 508-574-6264 Skype: labsafe; 508-401-7406

jim**At_Symbol_Here**labsafety.org www.labsafety.org Teach, Learn, and Practice Science Safely






On Wed, Jan 26, 2022 at 3:24 PM davivid <davivid**At_Symbol_Here**well.com> wrote:
Turns out the reported autoignition temperature for sulfur is as low as
168C. The dust is quite sensitive and hydrocarbon impurities are known
to decrease the autoignition temp.

http://www.sulphuric-acid.com/techmanual/Plant_Safety/safety_sulphur.htm

This is lower than that of red phosphorus at 260C.

https://web.stanford.edu/dept/EHS/cgi-bin/lcst/lcss/lcss72.html


Regards
Dave Lane
Principal
Clavis Technology Development

On 1/26/22 7:45 AM, Monona Rossol wrote:
> At last. My ppt has examples of all kinds of deflagration substances, but I haven't had a good one on sulfur. Monona
> CAUSE DETERMINED OF SULFUR FIRE AT CERES FARM COMPANY
> https://www.modbee.com/news/local/article257699048.html
> Tags: us_CA, industrial, follow-up, environmental, ag_chems
>
> The source of a hazardous materials fire that prompted a 12-hour shelter in place advisory for some Ceres residents on Monday was determined to be a light bulb.
>
> An employee at Stanislaus Farm Supply on East Service Road was changing a light bulb inside a 40,000-square-foot warehouse that contained a large amount of fertilizer-grade sulfur, said Dustin Bruley, supervisor of the Stanislaus Regional Fire Investigation Unit.
>
> "In those warehouses they have a lot of dust floating in the air attributed to that product and when you change out a light bulb the simplest spark or static electricity can set off the particulate that floats in the air," Burley said. In this case the particulate was flammable sulfur.
>
> He said the spark caused flash fire, "The air around it has this matter floating so when it ignites, anything in that room has the potential to ignite as well."
>
> A 500-ton pile of fertilizer sulfur began smoldering. Employees tried to put it out but the fire grew larger than they could handle.
>
>
> Twitter **At_Symbol_Here**acsdchas
>
> ---
> For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org
> Follow us on Twitter **At_Symbol_Here**acsdchas
>

---
For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org
Follow us on Twitter **At_Symbol_Here**acsdchas
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.