Subject: Re: [DCHAS-L] Cotton content of jeans

Date: Jul 30, 2013 19:07 UTC

Author: Monona Rossol <actsnyc**At_Symbol_Here**cs.com>

Next by Date

Subject: [DCHAS-L] Chemical Safety headlines from Google (15 articles)

Date: Jul 31, 2013 12:22 UTC

Author: Secretary, ACS Division of Chemical Health and Safety <secretary**At_Symbol_Here**DCHAS.ORG>

Subject context

From: Peter Zavon <pzavon**At_Symbol_Here**rochester.rr.com>

Subject: Re: [DCHAS-L] Lab Ventilation (ACH)

Date: Jul 31, 2013 01:37 UTC

Reply-To: DCHAS-L

In-Reply-To:  

Demystify: 

I try to avoid use of ACH as a ventilation performance criterion because the same ACH involves different volumes of air for differing floor areas and  ceiling heights.  Since these must play into the engineering design and cost, I think it best to start from the actual room size and intended use, look at supplemental exhaust that may be present (fume hoods, etc.) and use a total cfm performance requirement, especially when dealing with design considerations and engineers.

 

You can probably mathematically reduce this to CFM per unit volume of the room, which could be rendered as ACH, but I think it  makes criteria that are more divorced than necessary from the important parameters.

 

 

Peter Zavon, CIH
Penfield, NY

PZAVON**At_Symbol_Here**Rochester.rr.com

                                                                                                                                                                                                                                                        

 

 

From: DCHAS-L Discussion List [mailto:dchas-l**At_Symbol_Here**MED.CORNELL.EDU] On Behalf Of Alfred Bouziane
Sent: Tuesday, July 30, 2013 1:20 PM
To: DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU
Subject: [DCHAS-L] Lab Ventilation (ACH)

 

Dear DCHAS members:

 

What minimum air changes per hour (ACH) do your respective institutions require for the following laboratories while occupied?:

 

·         Instructional General Chemistry (no VOCs)

·         Instructional Organic Chemistry

·         Research (hazardous materials/volatiles)

 

Your thoughts/recommendations would be greatly appreciated.

 

Best,

 

ALFRED M. BOUZIANE | Project Manager

Environmental Health and Safety

A Department of Career and Protective Services

 

 

 