About This Archive | DCHAS-L 2014 Index | DCHAS-L Yearly Index | DCHAS-L Home Page
Sigma Aldrich has a SDS that says, "Heat sensitive. Store under inert gas" I don't agree with that statement but thought you should know about the ref. My experience says the inert gas recommendation is to prevent it from evaporating while storing. A liquid seal cap should negate the need for the inert gas too I think. Sent from my iPhone > On Apr 11, 2014, at 12:39 PM, "Ralph B. Stuart" <ralph.stuart**At_Symbol_Here**CORNELL.EDU> wrote: > > A lab tech noticed a statement on a Dichloromethane bottle that said "store under an inert gas". He would like to know if this is a safety recommendation or designed to maintain the quality of the chemical by avoiding exposure to environmental gases. From what I can find, it appears to be the latter, but I thought I would ask DCHAS-L to see if anyone knows of a safety reason for this recommendation. > > Thanks for any help with this. > > - Ralph > > > Ralph Stuart CIH > Chemical Hygiene Officer > Department of Environmental Health and Safety > Cornell University > > rstuart**At_Symbol_Here**cornell.edu