From: Kristi Ohr <kohr**At_Symbol_Here**UMASS.EDU>
Subject: Re: [DCHAS-L] Peroxide forming compound testing program
Date: Wed, 31 Jan 2018 13:56:34 +0000
Reply-To: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**PRINCETON.EDU>
Message-ID: dab7edac6072428892b239cb60d08de3**At_Symbol_Here**umass.edu
In-Reply-To <54EE03AFF14DA042AC76DC84AB79A6D542383F47**At_Symbol_Here**EXMB2.bnl.gov>


Hi Joe,

 

We just implemented a new program for management of peroxide forming materials. We are using the low range Quantofix test strips, and are doing a pass/fail instead of threshold value.  We are doing that for all classes of peroxide forming materials.

 

All the best,

 

Kristi

 

From: ACS Division of Chemical Health and Safety [mailto:DCHAS-L**At_Symbol_Here**PRINCETON.EDU] On Behalf Of Pavlak, Edmund J
Sent: Wednesday, January 31, 2018 7:35 AM
To: DCHAS-L**At_Symbol_Here**PRINCETON.EDU
Subject: [DCHAS-L] Peroxide forming compound testing program

 

Does anyone have a testing program in which peroxide forming chemicals are tested?  If so, what methodology are you using?  Do you have a threshold value for disposal, and is it for all peroxide formers or are there different thresholds specific to certain chemicals?

 

Thanks for your help.

 

Joe Pavlak

 