Safety Emporium eyewashes
Safety Emporium eyewashes

Interactive Learning Paradigms, Incorporated

DCHAS-L Discussion List Archive

About This Archive  |   DCHAS-L 2023 Index   |   DCHAS-L Yearly Index   |   DCHAS-L Home Page

About This Archive

DCHAS-L 2023 Index

DCHAS-L Yearly Index

DCHAS-L Home Page


Previous by Date

Subject: [DCHAS-L] Goodbye to chemical weapon stockpiles

Date: Jul 13, 2023 10:22 UTC

Author: Ralph Stuart <ralph**At_Symbol_Here**RSTUARTCIH.ORG>

Next by Date

Subject: Re: [DCHAS-L] Filling balloons with hydrogen gas

Date: Jul 13, 2023 15:56 UTC

Author: Craig Merlic <merlic**At_Symbol_Here**CHEM.UCLA.EDU>

From: James Kaufman <jkaufman**At_Symbol_Here**LABSAFETYINSTITUTE.ORG>

Subject: Re: [DCHAS-L] Filling balloons with hydrogen gas

Date: Jul 13, 2023 13:45 UTC

Reply-To: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**Princeton.EDU>

Message-ID: <CAHk9oEQz4zJbdszxSaQ5pXK8ZymGt4S-hNwyL2vZP7AtF_bmxQ**At_Symbol_Here**mail.gmail.com>

In-Reply-To: <CAF85TGQkE5EvywXgiL2vA40FA0fAr8msxJvN0AbCXV_yrExm2w**At_Symbol_Here**mail.gmail.com>

Demystify: 
There are several ways to ground and bond plastic and glass containers.  

Please contact me directly for more information ... Jim


PS.  LSI now has virtual lab inspections, safety program evaluations, document reviews, plus courses and seminars ... all virtual.  And, a complimentary,  updated version of our classic Laboratory Safety Guidelines is now available on our website ... https://www.labsafety.org/product/lab-safety-rules

 

James A. Kaufman, PhD

Founder/President Emeritus

 

The Laboratory Safety Institute (LSI)

A Non-profit Educational Organization

  for Safety in Science, Industry, and Education

192 Worcester Street, Natick, MA 01760-2252

(O) 508-647-1900   (F) 508-647-0062   (C) 508-574-6264  

Skype: labsafe; 508-401-7406  jkaufman**At_Symbol_Here**labsafety.org  www.labsafety.org 


Teach, Learn, and Practice Science Safely

 





On Wed, Jul 12, 2023 at 1:31 PM Alyssa Brand <abrand**At_Symbol_Here**lbl.gov> wrote:
Let me preface this with: I am no expert in the safe use of hydrogen gas. But I wonder why a balloon would be used rather than a dedicated, regulated gas line. My main concern with this would be the potential for ignition of the hydrogen due to a static electricity discharge, and I would think that using plastic components might not only increase the risk of a static discharge occurring, but prevent the use of bonding and grounding. If I'm entirely off base, feel free to ignore me. As I said, not an expert.

Alyssa

On Fri, Jul 7, 2023 at 10:54 AM davivid <davivid**At_Symbol_Here**well.com> wrote:
We do hydrogenations and hydrogenolysis in our lab in quantities of up
to several moles. The equipment is assembled in a hood. Hydrogen is
plumbed into the hood via 1/4" polyethylene tubing cable tied to the
drop ceiling from tanks located elsewhere in the lab. The hydrogen
regulator is set to deliver the lowest feasible pressure and the outlet
valve set to deliver the lowest feasible flow.

The assembled equipment is charged with the reactants and solvents then
evacuated using a small diaphragm pump in the hood through a stopcock. A
two-way stopcock can be used but a three-way stopcock is preferred as it
does not require disconnection of the tubing from the system when
switching between evacuation and fill. Hydrogen is then let into the
evacuated system via the stopcock and fills the balloon. The hydrogen
flow can be shut off at the system using the stopcock. If desired, the
evacuation and fill procedure can be repeated multiple times to flush
residual air from the system.

We use mylar balloons from the Dollar Store as they are more capacious,
stronger, less permeable, and more solvent resistant than rubber
balloons. If you go this route you will need to fit the tubing several
inches into the mouth of the balloon to reach past the internal valve.

The attached photo shows the method we use to connect the balloons to
the system. A gas inlet adapter is fitted with Tygon tubing which then
connects to 1/4" polyethylene tubing. The joint between the two types of
tubing is secured by two wraps of cable tie and sealed with grease. The
tubing extends into the balloon to the point indicated by the arrow. The
joint between the balloon and the 1/4" line is sealed with grease and
fastened by wrapping several times with the ribbon from the balloon.

Best regards
Dave Lane
Chief Science Officer
Artisyn Laboratories



On 7/6/23 12:27 PM, Laura Cunningham wrote:
> Hi all,
>
> Does anyone have recommendations on how to *safely* fill a balloon with hydrogen? The hydrogen tank in this scenario is in an open lab, and the hydrogen filled balloon is for a hydrogenation reaction. The gas tank is located close enough to a fume hood that piping the hydrogen into the fume hood might be feasible. Wondering what other people’s experiences have been with this.
>
> Thanks,
> Laura
>
> Sent from Proton Mail for iOS
>
> ---
> For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org

---
For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org
--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org

Previous post  |  Top of Page  |  Next post