Subject: [DCHAS-L] CHAS Fall Workshop series schedule

Date: Sep 21, 2023 14:26 UTC

Author: Mary Beth Koza <mbkoza2**At_Symbol_Here**GMAIL.COM>

Next by Date

Subject: Re: [DCHAS-L] Curious about Teflon tape

Date: Sep 21, 2023 23:27 UTC

Author: Tammy M. Lutz-Rechtin <tlutzrec**At_Symbol_Here**UARK.EDU>

From: Michael McCutcheon <0000153f1ee0b856-dmarc-request**At_Symbol_Here**LISTS.PRINCETON.EDU>

Subject: Re: [DCHAS-L] Curious about Teflon tape

Date: Sep 21, 2023 17:41 UTC

Reply-To: Michael McCutcheon <jmmchemist**At_Symbol_Here**YAHOO.COM>

Message-ID: <409722077.1073617.1695318067453**At_Symbol_Here**mail.yahoo.com>

In-Reply-To: <CAJug0Owgrij=pjNdNiG4MMKjHWxYRGUnHAmew_a_ef1_AGtS6g**At_Symbol_Here**mail.gmail.com>

Demystify: 
Hi Ben,

The connections (fittings) on a compressed gas cylinder are CGA fittings and are designed such that the metallic mating surfaces create the mechanical, gas tight, seal; different than tapered thread type fittings, such as NPT, that require some sort of sealing compound such as Teflon tape to create a gas tight seal at the threads as opposed some sort of mating surface.  With CGA, flare, or other "compression type" fittings, the use of Teflon tape can actually create leaks because it prevents the mating surfaces from creating a mechanical seal.  There are very few fittings that require the addition of tape or compound to create a seal.  If you are getting leaks from a "compression type" fitting, it is because there is debris or some sort of damage to the mating surfaces and tape or compound will not fix it; must be replaced. 

See the following article from Airgas on the The “Do’s and Don’ts” of CGA Cylinder Connections
 
https://www.airgas.com/resources/cleanpeaks/2017/winter/cylinder-connections 

J. Michael McCutcheon


On Wednesday, September 20, 2023 at 01:52:56 PM PDT, Benjamin Ruekberg <bruekberg**At_Symbol_Here**uri.edu> wrote:


Hello,

This is nothing to get excited about, just a matter of curiosity.

At our annual safety training we were told not to use Teflon tape when attaching regulators to gas cylinders.  The ultimate reason given was that the tape would not allow the regulator's ball to fit tightly to the gas cylinder's socket.

I find this a bit difficult to believe.  This would only apply if the threads on the regulator and the cylinder were tapered.  Because a tapered thread connection stops going in once the male and female diameters are the same, using tapered threaded parts would require highly precise machining so that the male would stop going in at the precise distance to firmly seat the ball in the socket.  Such precision would be prohibitively expensive. (I think.)

Rather I think the reason is because white Teflon tape is not 100% Teflon and the other component is combustible.  There is a green Teflon tape for use with oxidizers that is 100% Teflon.  To avoid the use of the more common tape on an oxygen cylinder, the easiest way is to say "No Teflon tape on gas cylinders."

When appropriately used, the Teflon tape acts as a lubricant, so that a regulator can be put on (and taken off) without the use of an enormous wrench.

I know that I may be entirely wrong about this, so I am seeking the expert opinion of L-CHASers.

Thank you very much,

Ben