Subject: Re: [DCHAS-L] Gas Sensor

Date: Aug 10, 2026 12:04 UTC

Author: rpalluzi**At_Symbol_Here**verizon.net <000006c59248530b-dmarc-request**At_Symbol_Here**LISTS.PRINCETON.EDU>

Next by Date

Subject: [DCHAS-L] Abstract Submission Is Now Open for ACS Spring 2027

Date: Aug 10, 2026 13:47 UTC

Author: Monica Soma Hensley <monica.nyansa**At_Symbol_Here**GMAIL.COM>

Thread context

From: Harry J. Elston <harry**At_Symbol_Here**MIDWESTCHEMSAFETY.COM>

Subject: Re: [DCHAS-L] Gas Sensor

Date: Aug 10, 2026 12:25 UTC

Reply-To: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**PRINCETON.EDU>

In-Reply-To: [DCHAS-L] Gas Sensor

Demystify: 
Ruth Ann:

"Required" - no.

"Nice to have" - depends on the intended use and what you're trying to find out by having a sensor.

Oxygen sensors for enclosed spaces will warn you there's a low oxygen concentration issue.  I've seen these systems in enclosed spaces that don't have a lot of activity in them.  Generally speaking, if you're in a space that has a catastrophic failure of a LN2 Dewar, you know it happens and it's time to leave Dodge City.

There's a serious downside of placing sensors and monitors all over the place where there really aren't needed:  Maintenance.  The "best if used by" date that's on the package is a suggestion.  It was derived by placing the sensor in a perfect environment to measure its lifetime.  Texas, or anywhere else for that matter, is not the perfect ambient environment.  Elston's rule on sensors:  Change them twice as often as what is stated on the package.  Three times if you work in hot, humid environment.  Humidity is the enemy of most sensors.

Good luck

Harry

On Mon, Aug 10, 2026 at 6:47 AM Murphy, Dr. Ruth Ann <000019862d8e7db2-dmarc-request**At_Symbol_Here**lists.princeton.edu> wrote:

Good Afternoon,

 

Are gas sensors required in chemistry labs with natural gas utilities and/or liquid nitrogen use?  If so, what type of sensor is needed?  Thank you!

 

Best,

 

Ruth Ann Cook Murphy, PhD

Professor of Chemistry

University of Mary Hardin-Baylor

900 College Street

Belton, TX 76513

(254) 295-4542