DCHAS-L Discussion List Archive
From: Jeffrey Lewin <jclewin**At_Symbol_Here**MTU.EDU>
Subject: Re: [DCHAS-L] Glassware injury lesson learned report?
Date: Thu, 2 Jul 2015 12:49:25 -0400
Reply-To: DCHAS-L <DCHAS-L**At_Symbol_Here**MED.CORNELL.EDU>
Message-ID: CAEwQnqikoo+1xumQAegCRcFD9GSSzJ9HvE6zyrEW6xGRmNMhmg**At_Symbol_Here**mail.gmail.com
In-Reply-To
We've had numerous injuries over the years with students inserting pipets in into "handypette pumps" such as:
Students would hold the pipet too far away and break them and stab their hands. This led to several solutions of varying results:
Training student before every lab (still got injuries)
Bbuying enough units that we could set them up in advance so students did't have to insert pipets. Worked very well although sometime the pipets came loose or students still tried to change them.
One accidental solution was when an instructor bought less expensive plastic disposable pipets, but discovered they could be washed and reused multiple times. The unintended positive is that the plastic one were much sturdier and didn't break.
We've had similar "stabbing" injuries when people try to insert glass tubes or thermometers into rubber stoppers and have actually added individual instructions in our departmental safety manual about using lubricant when doing such insertions.
Jeff
Previous post | Top of Page | Next post