Ed,

 

I saw this spec coming down the pipeline. We don't use it as it is intended to apply to the smaller consumer type 3D printers used for classroom, office, and home use. Also, it does not address any issues related to offensive odors.

 

While you could use this standard to test larger units used in industrial type settings/prototype shops, I don't quite see the point on testing those. Aside from the harmful emissions, 3D printers also have offensive odors. Large units can stink up a warehouse. So, these things should always be vented to the outside.

 

It looks like you can use the UL test data to decide if ventilation is "technically" required. Since the pass/fail criteria is expressed in emitted mass/room volume, I think you would need to look at Appendix B to ensure the model used to calculate the Pass/Fail criteria is applicable to your building. Looking at the residential model, my house is average for my area. However, it is smaller than the national average home used in the model. Thus, if I had a certified unit in my house, the actual exposure would be higher that the spec allows.

 

I suspect the UL spec will become a requirement for all 3D printers sooner or later. Until then, I'm asking for ventilation on ours.

 

By the way, I'm talking about plastic printers. 3D metal printers have no business being used without hard-plumbed ventilation regardless of their size.

 

Yaritza Brinker

260.827.5402

 

From: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**PRINCETON.EDU> On Behalf Of Chainani, Edward Torres
Sent: Tuesday, March 10, 2020 1:14 PM
To: DCHAS-L**At_Symbol_Here**PRINCETON.EDU
Subject: [DCHAS-L] 3D printer emissions and UL 2904

 

** External Email **

Dear DCHAS community:

 

We don't have formal policies for 3D printers, but whenever I get wind of a new 3D printer being purchased and installed, I have been thinking of ensuring that there is an enclosure with local exhaust ventilation when there are no emissions data available.
 
Now, there is a newly released UL standard (UL 2904 - a Standard Method for Testing and Assessing Particle and Chemical Emissions from 3D Printers):

https://www.shopulstandards.com/ProductDetail.aspx?UniqueKey=35397
(You can view it online without purchasing it, if you create an account)
 
A technical brief is found here:
https://chemicalinsights.org//wp-content/uploads/2019/05/3DPrint_Standard_Brief_Version-2.pdf
 
This standard specifies the testing methodology as well as the maximum allowable concentrations of target chemicals and particles, in office, classroom and residential models. I expect that 3D printers on the market will soon being tested using this new standard.  In fact, one 3D printer manufacturer has provided me with the report of their product tested using the new UL standard with results for the various filaments that they supply.  I understand that they can't test for everything specified in the standard, but the report provided by the manufacturer shows they tested for ultrafine particles, TVOCs and 23 chemicals, and the results shows emission rates below the UL 2904 criteria for an office. I take this to imply that there will be minimal exposure when this 3D printer is placed in an office with the typical office ventilation.
 
Have any of you started vetting 3D printers using this standard?
 

Regards,
Ed

Edward Chainani, Ph.D.
Assistant Director for Safety
The Grainger College of Engineering Office of Safety
University of Illinois Urbana-Champaign
1308 W Green St
Urbana, IL 61801
Phone: (217)244-5594
Email: echaina2**At_Symbol_Here**illinois.edu
Web: http://officeofsafety.engineering.illinois.edu/

"Safety is a dynamic non-event; we have to work very hard so nothing will happen" -James Reason


--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org Follow us on Twitter **At_Symbol_Here**acsdchas




Electronic Transmission Confidentiality Notice

The information contained in this electronic transmission is private, confidential, the property of the sender, and intended for the use of the recipient(s), only. If you are not the addressee, any disclosure, copying, distribution or use of this information for any purpose is strictly prohibited. If you have received this information in error, please notify the sender, YBrinker**At_Symbol_Here**fele.com, immediately by e-mail and then delete this message. Thank you.
[FE.EN.1]

Previous post   |  Top of Page   |   Next post



The content of this page reflects the personal opinion(s) of the author(s) only, not the American Chemical Society, ILPI, Safety Emporium, or any other party. Use of any information on this page is at the reader's own risk. Unauthorized reproduction of these materials is prohibited. Send questions/comments about the archive to secretary@dchas.org.
The maintenance and hosting of the DCHAS-L archive is provided through the generous support of Safety Emporium.