Previous by Date

Subject: Re: [DCHAS-L] Phenolphthalein or Replacement?

Date: Nov 13, 2025 23:02 UTC

Author: Stephen Taylor <stephen**At_Symbol_Here**LABSAFETYINSTITUTE.ORG>

Next by Date

Subject: [DCHAS-L] Bibulous Paper Disposal

Date: Nov 13, 2025 23:49 UTC

Author: Filiberto Palacios <00001f5128a5fa0b-dmarc-request**At_Symbol_Here**LISTS.PRINCETON.EDU>

From: Ryan, Patrick <00002325d83b98ec-dmarc-request**At_Symbol_Here**LISTS.PRINCETON.EDU>

Subject: Re: [DCHAS-L] Phenolphthalein or Replacement?

Date: Nov 13, 2025 23:16 UTC

Reply-To: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**Princeton.EDU>

Message-ID: <SJ2PR02MB938922DB963C03D09356DB36BCCDA**At_Symbol_Here**SJ2PR02MB9389.namprd02.prod.outlook.com>

In-Reply-To: <48CE82CB-AE37-405E-A20B-79DC37A67C2C**At_Symbol_Here**ilpi.com>

Demystify: 

Rob,

 

Drain disposal prohibitions are usually related to regional and/or municipal discharge permits that affect drain disposal requirements and may also involve “40 CFR 403.5(b) - National Pretreatment Standards: Prohibited Discharges”.  These involve drain disposal where effluent may interfere with a POTW (Publicly Owned Treatment Works).

More Information:
https://www.ecfr.gov/current/title-40/chapter-I/subchapter-N/part-403/section-403.5

40 CFR 403.5 -- National pretreatment standards: Prohibited discharges.

 

Your reference of 40 CFR 372.38(a) indeed involves EPCRA & TRI Reporting relates to Toxic chemical release reporting requirements for facilities in certain industries handling a TRI-listed chemical, and manufacturing, processing, or using that chemical above a specific threshold quantity.  

https://www.epa.gov/toxics-release-inventory-tri-program

 

EPA regulations are vast and knowing which regulations apply to a specific situation is the key.

 

Patrick A. Ryan, CIH, CSP, CHMM

 

 

From: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**Princeton.EDU> On Behalf Of Info
Sent: Thursday, November 13, 2025 12:34 PM
To: DCHAS-L**At_Symbol_Here**Princeton.EDU
Subject: Re: [DCHAS-L] Phenolphthalein or Replacement?

 

**External Sender**

Wow, Patrick, this is getting interesting!  I did find phenolphthalein listed in Table 1 of 40 CFR Part 372.65 with some other Nasty Things: https://www.ecfr.gov/current/title-40/chapter-I/subchapter-J/part-372/subpart-D But this is apparently TRI/SARA rather than anything to do with water or wastewater, per se.

 

Anyway, it’s worth noting that minimal laboratory use is apparently exempted per 372.38(a), de minimus concentration of a toxic chemical in a mixture as well as (d) activities in laboratorieshttps://www.ecfr.gov/current/title-40/chapter-I/subchapter-J/part-372/subpart-B/section-372.38  Which goes right to David’s and my point. But, again, I know nothing of the interface between this regulation and any others.

 

If anyone might enjoy what appears to be some AI slop on the topic, I found this article: https://eureka.patsnap.com/report-research-on-phenolphthalein-in-accelerated-wastewater-treatment-mechanisms 

 

Best wishes,

 

Rob Toreki

 

LabLocks™ - The first device that can lock out standard laboratory ball valves: https://www.safetyemporium.com/07400

US-Made NIOSH and FDA-approved N95 respirators: https://www.safetyemporium.com/safety-items/respirators/

 

Safety Emporium - Laboratory and Safety Supplies 
https://www.SafetyEmporium.com
esales**At_Symbol_Here**safetyemporium.com  or toll-free: (866) 326-5412
Fax: (856) 553-6154, PO Box 1003, Blackwood, NJ 08012



On Nov 13, 2025, at 10:56AM, Ryan, Patrick <00002325d83b98ec-dmarc-request**At_Symbol_Here**LISTS.PRINCETON.EDU> wrote:

 

All,

 

The *D022 code specifically refers to the chemical *Chloroform, not phenolphthalein.  Phenolphthalein has no D022 waste code.

 

Patrick A. Ryan, CIH, CSP, CHMM

 

From: ACS Division of Chemical Health and Safety <DCHAS-L**At_Symbol_Here**Princeton.EDU> On Behalf Of David EldrEdge
Sent: Wednesday, November 12, 2025 4:51 PM
To: DCHAS-L**At_Symbol_Here**Princeton.EDU
Subject: Re: [DCHAS-L] Phenolphthalein or Replacement?

 

**External Sender**

Hi Rob,

 

I see where you are coming from. I am virtually on the same page, and I brought your argument up with our EHS representative.

 

This is the reply.

 

"Phenolphthalein should not be poured down the drain. It is classified by the EPA as a toxic hazardous waste (D022) under 40 CFR §261.24 – Toxicity Characteristic due to its potential carcinogenic properties. 

Any solutions, residues, or contaminated materials containing phenolphthalein must be collected and disposed of through the hazardous waste program, not through the sanitary sewer. 

Please label any waste containers as “Phenolphthalein Waste – Toxic (D022)” and store them in your designated hazardous waste accumulation area until Environmental Health & Safety can arrange for proper disposal. Hope this helps"

 

I have not had any firm responses about other indicators such as  bromthymol blue. I am led to believe then, this is a safe alternative to phph and we can therefore send our neutralized NaOH and HCl, down the drain with  bromthymol blue.

 

 

 

David EldrEdge

Co-Owner

NALTIC Industrials, LLC

888.891.0077 Main

435.503.4972 Cell

435.767.7714 Google Voice & Text

435.654.2727 Fax

 

 

 

~WRD0000.jpg

 

On Wed, Nov 12, 2025 at 12:42PM Info <info**At_Symbol_Here**ilpi.com> wrote:

I am a complete neophyte with respect to waste regulations. Can someone please explain why this conversation is even happening? I can’t see any statistically possible way pouring this down the drain poses a risk to anyone or anything. To wit: 

 

Phenolphthalein is normally used as a 1% by mass solution at most - usually 0.1% if titrating a dilute or weak acid. And one uses one or two drops per titration; maybe three if 0.1%.

 

So even if I had a full lab class of 24 students and each did 3 titrations that afternoon, that’s maybe 150 or even 200 drops - less than half an ounce.

 

Half an ounce is about 15 mL. At 1% by mass that’s  0.15 g of phenolphthalein,  150 mg.  Figure with glassware washing and whatnot, each student is going to put at least 4 gallons down the sink so call it 100 gallons total, or 400 liters in round numbers. 

 

Phenolphthalein has a molar mass of 318 g/mol, so we’re talking 0.0004717 moles. In 400 liters of water. So it’s 0.00000118 molar.  Which is 0.375 ppm in the waste stream. And that’s before being diluted by the rest of the building and campus which will take that down another couple orders of magnitude.

 

1. I doubt any wastewater authority would be looking for, let alone be able to detect, what will ppb levels of the stuff where it hits the monitoring point.

 

2. Sure, phenolphthalein is a suspected human carcinogen but according to the 15th NTP Rerpot on Carcinogens “The data available from epidemiological studies are inadequate to evaluate the relationship between human cancer and exposure specifically to phenolphthalein.”  And that’s from looking at people that ingested 5-10 mg (or more) orally over long periods of time (to get a 5 mg dose from our 0.375 ppm waste stream would require drinking 13 liters of it). Even in the rodent models, it took fantastically high dosages to produce effects (hundreds or thousands of ppm daily). 

 

3. So this clearly comes down to Regulations somewhere.

 

So, what specific Regulation is being applied here, is it bound by hazard (regardless of risk) vs the risk (which is based on the actual amount) or some absolute ppm level, and is this something local wastewater authorities can mandate on their own?

 

Thanks,

 

Rob Toreki

 


 =================================================
   Interactive Learning Paradigms, Incorporated (ILPI)
Training, environmental/occupational health & safety consulting
Ph: (856) 449-8956, Fax: (856) 553-6154, sales**At_Symbol_Here**ilpi.com
                                         http://www.ilpi.com/
Lab & safety supplies?  Visit https://www.SafetyEmporium.com/




On Nov 11, 2025, at 4:28PM, Jeffrey Lewin <jclewin**At_Symbol_Here**MTU.EDU> wrote:

 

When I checked a couple of SDSs for phenolphthalein solution they indicated they were mixed with ethanol and had a flashpoint below 60c, which makes the stock solution ignitable and a characteristic hazardous waste.  Presumably you are diluting it as part of a reaction.  If the alcohol is diluted to less than 24% it is no longer a characteristic hazardous waste (by definition) but may still be ignitable and prohibited by the sewer authority.

 

I found two different SDSs for bromothymol blue solution, one of which used IPA and, again, a flashpoint less than 60C.

 

But, even if you use an aqueous based dye you might still be not allowed to sewer it; some sewer authorities have prohibitions from dyes being sewered.

 

Hence, it should be collected for waste disposal, the question is does it meet the RCRA definition of a hazardous waste (EPA code D001) or is it collected and disposed of as a nonRCRA (Liquid Industrial Byproduct in MI) waste?

 

Jeff

 

 

On Tue, Nov 11, 2025 at 9:01AM David EldrEdge <Dave.EldrEdge**At_Symbol_Here**naltic.com> wrote:

Our School's EHS responded to a question that was brought up about phenolphthalein:

 

"I verified this with the wastewater district, and they confirmed that it [phenolphthalein] cannot be disposed of down the drain. I want to be cautious here if we start discharging materials improperly, it could trigger a wastewater audit and potentially open Pandora’s box for the college."

 

What do you all do? Are you still using phenolphthalein or have you replaced phenolphthalein with something like bromthymol blue or something similar?  Do you get the same results or better? 

 

or...

 

Are you still using phenolphthalein, if so how do you deal with the waste? If collecting the waste, is it worth the cost of disposal? 

 

Warm regards,

 

David EldrEdge

Co-Owner

NALTIC Industrials, LLC

888.891.0077 Main

435.503.4972 Cell

435.767.7714 Google Voice & Text

435.654.2727 Fax

 

 

~WRD0000.jpg

--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org


 

-- 

Jeff Lewin 

Chemical Safety

Environmental Health and Safety

Office of the General Counsel

Michigan Technological University

 

--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org

 

--- For more information about the DCHAS-L e-mail list, contact the Divisional membership chair at membership**At_Symbol_Here**dchas.org